Student housing and build-to-rent flooring: SPC and LVT that can be repaired plank by plank between tenancies.
Six questions from residential operators · Area by area · Builds and sizes · Order checklist
Six questions from student housing and build-to-rent operators,
answered directly.
Can damaged planks be replaced between tenancies?
Yes. Loose lay planks lift out one by one. Click planks are replaced by unclicking from the nearest wall or with the repair method in the installation instruction. Glue-down LVT is replaced by lifting the damaged plank and re-bonding a new one. Keep spare cartons from the same production run for repairs.
Do you have impact sound data between flats?
We hold North American ASTM results: ΔIIC 21 for a 6.5 mm SPC with 1.5 mm IXPE, and ΔIIC 22 for a 5 mm SPC with 1 mm IXPE, on a 150 mm concrete slab. We hold no ΔLw test to EN ISO 717-2. Where the building regulations need ΔLw or a site test, the acoustic consultant decides the build-up.
Which fire class can you document?
An SPC build of 4.0 mm total with a 0.3 mm wear layer is classified Bfl-s1 to EN 13501-1, and an EN 14041 type test records Bfl for another PVC build. The reports cover those builds only, not the 5–8 mm SPC click builds with attached IXPE. The class your building needs is set by the fire engineer or the specification; send it with the build you want.
Which wear layer for a student room or a rental flat?
SPC click comes with 0.30–0.70 mm wear layers; click LVT and glue-down LVT have their own ranges on each data sheet. Choose by traffic and the refurbishment cycle you plan, and approve a sample. We do not state a service life in years.
Will later phases match the first building?
Order a décor for several phases in one production run where possible. If phases ship separately, approve a sample from each run before loading. Keep the same build, décor and surface on the specification for every phase.
Can room floors and amenity floors share a container?
Yes. SKUs can share a container; each design or colour has its own minimum, confirmed in the quotation. The loading plan shows what fits, because heavier builds reach the weight limit before the container is full.
Residential flooring area by area:
what to check and who confirms it.
Operators judge a floor by how quickly a room is back in use. We answer for the build and its documents; the designer, fire engineer and acoustic consultant set the requirement; the installer confirms the base.
Build, thickness, wear layer, data sheet, test reports with their scope, spare cartons.
Ecoflors documents, per buildFire class, acoustic target and test method, wear layer, décor.
Designer, fire engineer, acoustic consultantRepair method, spare stock, cleaning, turnover programme.
Operator and installer| Area | Builds to consider | What to check in the specification | What Ecoflors provides |
|---|---|---|---|
| Student rooms and studios | SPC click with attached IXPE; loose lay | Acoustic target; plank replacement; wear layer | ASTM impact-sound results for two SPC builds; data sheet per SKU |
| Apartments | SPC click; click LVT on a flat screed | Acoustic target; underfloor heating if any | Installation instruction per SKU |
| Corridors and stairs | Glue-down LVT | Fire class for the escape route; slip; rolling loads | Bfl-s1 for the tested SPC build; ISO 10582 pass for a 3.0 mm glue-down build |
| Kitchens and amenity | Glue-down LVT; stone-look tiles | Slip; cleaning regime | R10 for the tested surface |
| Gyms and cinemas | Per the operator’s brief | Point loads, impact, acoustic isolation | We confirm suitability per build, or say it is not a fit |
The area suggestions are starting points for the designer, not a replacement for the building specification.
Documents available
For specifiers and contractors: each report covers only the build tested. Before the order we check whether a report matches the SKU, thickness, wear layer and surface you are buying, and tell you when it does not. Report and certificate numbers are sent on request, with their scope. Data sheets and reports are in English.
| Scheme or report | Build tested / scope | Result or validity | Note |
|---|---|---|---|
| Reaction to fire, EN 13501-1 (Intertek, July 2022) | SPC floor, 4.0 mm total, 0.3 mm wear layer | Bfl-s1 | European classification; the build tested only. Not the 5–8 mm SPC click builds with attached IXPE. |
| EN 14041 type test (Intertek, January 2021) | One PVC floor covering build: multilayer with glass-fibre mesh, 2–10 mm total | Reaction to fire Bfl; formaldehyde E1; slip class DS | Covers that build, not all SPC, LVT, ABA or wall panels. |
| Impact sound, ASTM method (Intertek) | 6.5 mm SPC (5 mm board + 1.5 mm IXPE) on a 150 mm concrete slab; a 5 mm SPC (4 mm + 1 mm IXPE) in a separate test | ΔIIC 21 (6.5 mm); ΔIIC 22 (5 mm) | North American method. Not a ΔLw result to EN ISO 717-2; we hold no ΔLw test. |
| Glue-down LVT performance, ISO 10582 (Intertek, August 2023) | Glue-down LVT 3.0 mm, 0.3 mm wear layer | Thickness, stability and curling, residual indentation, colour fastness, squareness and castor chair: pass | The build tested only. |
| Slip, DIN 51130 (Intertek, August 2022) | SPC surface described in the report | R10 | Ramp test; the surface tested only. Not a pendulum result. |
| VOC emissions test (Eurofins, April 2026) | One PVC floor, 8.0 mm | Indoor Air Comfort GOLD limit values; AgBB; formaldehyde E1 | The tested sample only; a test report, not a product certificate. |
| FloorScore (SCS) | SPC up to 7 mm; ABA up to 7 mm; LVT up to 5 mm; loose lay up to 6 mm | Valid to 30 September 2027 | Voluntary indoor-emissions certification. 8 mm SPC and ABA are outside this scope. |
| GREENGUARD Gold (UL 2818) | Click vinyl 3.2–7.0 mm; glue-down 2.0–7.0 mm; loose lay 3.2–7.0 mm | Valid to 7 January 2027 | Voluntary VOC certification. Checked per SKU and build. |
| EPD, EN 15804 (SCS Global Services) | SPC, LVT and PP floors; European market scenario | Valid to 27 April 2031 | Voluntary; useful where a project scores environmental data. |
A report that matches your build supports the project file; on its own it does not show that a national or project requirement is met. Scope: SPC and LVT certifications.
SPC click, SPC tiles and click LVT:
builds and sizes in millimetres.
Every standard SKU has a data sheet. Not every size is made in every thickness; the grade table is on each product page. Décors are in the décor library.
Plank with a rigid mineral and PVC core, décor film and wear layer, with attached IXPE underlay. For distributor stock, apartments, offices and shops.
Stone, marble, concrete and terrazzo décors in tile formats: SPC click, flexible click, glue-down, loose lay and ABA. For retail, offices and hospitality, subject to the project specification.
Flexible vinyl with a glass-fibre reinforced core, softer underfoot than SPC. No attached underlay. For apartments, villas and hospitality on a flat, well-prepared screed.
SPC core with vinyl layers above and below and attached IXPE: a rigid plank with a vinyl backing.
Thin vinyl bonded to a level screed. For malls, retail units, offices, clinics and hotels with heavy traffic, and for herringbone layouts.
Heavy vinyl with a non-slip backing and no click, replaced plank by plank. Depending on the product, area and traffic, it may need perimeter fixing or a tackifier.
On site: a floating floor needs a flat, dry and sound base; a glue-down floor needs a level surface suitable for the adhesive. Keep spare cartons from the same production run on site for repairs. See the installation guide.
Herringbone, surface, SPC wall panels and own brand
Each option is confirmed by build in the quotation.
Herringbone
A and B click boards in SPC, flexible LVT and ABA, or glue-down LVT, each with its own data sheet. For SPC click herringbone, A and B boards are packed in separate cartons.
Herringbone formats and data sheets
Chevron
Ends cut at an angle so the boards meet in a continuous point. Sizes depend on the build and the project.
Chevron formats
EIR surface
Embossed in register: the texture follows the printed grain. Available on selected wood décors, at a higher price than the standard texture.
EIR décors
Own brand (OEM)
Your brand, carton and label, quoted by build, with the minimum order confirmed for your programme. One specification can run across several buildings.
OEM and private label
SPC wall panels
For feature walls and corridors, depending on the panel, substrate and fixing method. Floor fire reports do not cover wall panels. Ask for floor and wall in the same enquiry.
SPC wall panels
Production line
Made at our factory in Jiaxing, China. Production time and loading date are confirmed in the quotation. The photo shows production, not a test result.
About Ecoflors| Item | What we need from you |
|---|---|
| Areas | Rooms, apartments, corridors, amenity, with m² per area |
| Build | SPC click, click LVT, glue-down LVT or loose lay; thickness and wear layer if known |
| Requirements | Fire class and acoustic target named in the design |
| Décors | Décor references or a target visual |
| Phasing | Handover dates and whether phases ship separately; spare cartons |
| Delivery | Your forwarder and port, or the importer handling the scheme |
Tariff classification for importers: HS 3918.10 for vinyl and SPC flooring.
Resources for your purchase
Samples and a quotation
in one request.
One form for samples, a quotation or both. To start we only need your company, a business contact and what you need. Leave open what is not settled yet.
If you like, pick décors first; they carry over to the form.
- Pick décorsAdd décors to your list in the décor library.
- Set the buildTick SKUs on a product page or describe the build in the form.
- Send one formTick Samples, Quotation or both. We reply by email.
Read the sample and courier policy before requesting samples. Privacy policy: ecoflors.com/privacy-policy.
General information for trade buyers and specifiers. Building, fire, acoustic, slip and procurement requirements differ by country and project; confirm them with the designer, fire engineer and client before ordering. Test results refer to the samples tested; whether they apply to an order is confirmed by comparing the build and the SKU.