School and education flooring: vinyl and PVC-free floors with the emission, fire and wear documents for each build.
Six questions from school projects · Area by area · Builds and sizes · Order checklist
Six questions from school and education projects,
answered directly.
Which emission documents can you supply?
FloorScore covers SPC up to 7 mm, ABA up to 7 mm, LVT up to 5 mm and loose lay up to 6 mm; GREENGUARD Gold covers click vinyl 3.2–7.0 mm, glue-down 2.0–7.0 mm and loose lay 3.2–7.0 mm. A Eurofins test of one 8.0 mm PVC floor met the Indoor Air Comfort GOLD limits and AgBB. We check the scope against the SKU before the tender is priced.
The tender excludes PVC. What can you offer?
Our PP floor is PVC-free and carries Blue Angel (DE-UZ 120) for 2.0–7.0 mm with surface coating and without underlay, plus CE under EN 14041 (system 1). These documents cover the PP floor only, not our SPC or LVT.
Will classroom chairs and castors damage the floor?
A 3.0 mm glue-down LVT with a 0.3 mm wear layer passed the ISO 10582 tests, including residual indentation and the castor chair test. Felt pads on chair legs are still advised. For other builds we compare the data sheet; we do not extend that result to them.
Which fire class can you document?
An SPC build of 4.0 mm total with a 0.3 mm wear layer is classified Bfl-s1 to EN 13501-1, and an EN 14041 type test records Bfl for another PVC build. The reports cover those builds only, not the 5–8 mm SPC click builds with attached IXPE. The class your building needs is set by the fire engineer or the specification; send it with the build you want.
What slip data do you hold?
R10 on the DIN 51130 ramp for the SPC surface in the report, and P4 on the AS 4586 wet pendulum for a 4.2 mm SPC sample. We hold no own pendulum test to BS 7976 or EN 16165. Wet areas, ramps and entrances need the test the specification names, on the surface you order.
Do your floors have an antimicrobial treatment?
We do not claim an antimicrobial treatment or test for our floors. Where a tender asks for one, tell us in the enquiry; we will not tick it without a report. Cleaning follows the maintenance guidance for the SKU.
School flooring area by area:
what to check and who confirms it.
Schools are specified by tender, often with environmental criteria and a fixed handover date in the holidays. We answer for the build and its documents; the designer and the client set the requirement; the installer confirms the base.
Build, thickness, wear layer, data sheet, emission and fire reports with their scope.
Ecoflors documents, per buildEmission criteria, PVC-free clause, fire class, slip test, environmental data.
Designer, client, procurementBase flatness and moisture, adhesive, expansion gaps, holiday programme.
Installer, to the installation instruction| Area | Builds to consider | What to check in the specification | What Ecoflors provides |
|---|---|---|---|
| Classrooms | Glue-down LVT; SPC click; PP floor where PVC is excluded | Chair and castor wear; emission criteria | ISO 10582 pass for a 3.0 mm glue-down build; FloorScore and GREENGUARD Gold scope |
| Corridors and stairs | Glue-down LVT | Fire class for the escape route; slip; stair nosings | Bfl-s1 for the tested SPC build; R10 for the tested surface |
| Dining halls | Glue-down LVT | Slip in wet areas; cleaning regime | Slip reports with their scope |
| Libraries and quiet rooms | SPC click with IXPE; click LVT | Acoustic target and test method | ASTM impact-sound results for two SPC builds; no ΔLw test |
| PVC-free specifications | PP floor | Exact wording of the PVC-free clause | Blue Angel and CE (system 1) for the PP floor |
| Environmental scoring | All builds covered by the EPD | Which data the scheme scores | EPD to EN 15804 for SPC, LVT and PP floors, valid to April 2031 |
The area suggestions are starting points for the designer, not a replacement for the tender specification.
Documents available
For specifiers and contractors: each report covers only the build tested. Before the order we check whether a report matches the SKU, thickness, wear layer and surface you are buying, and tell you when it does not. Report and certificate numbers are sent on request, with their scope. Data sheets and reports are in English.
| Scheme or report | Build tested / scope | Result or validity | Note |
|---|---|---|---|
| FloorScore (SCS) | SPC up to 7 mm; ABA up to 7 mm; LVT up to 5 mm; loose lay up to 6 mm | Valid to 30 September 2027 | Voluntary indoor-emissions certification. 8 mm SPC and ABA are outside this scope. |
| GREENGUARD Gold (UL 2818) | Click vinyl 3.2–7.0 mm; glue-down 2.0–7.0 mm; loose lay 3.2–7.0 mm | Valid to 7 January 2027 | Voluntary VOC certification. Checked per SKU and build. |
| VOC emissions test (Eurofins, April 2026) | One PVC floor, 8.0 mm | Indoor Air Comfort GOLD limit values; AgBB; formaldehyde E1 | The tested sample only; a test report, not a product certificate. |
| Blue Angel, DE-UZ 120 | PP (PVC-free) floor 2.0–7.0 mm, with surface coating, without underlay | Awarded April 2026 | Covers the PP floor only, not SPC or LVT. |
| CE, system 1, EN 14041 | PP (PVC-free) floor | Factory production control assessed (May 2025) | PP floor only. |
| Glue-down LVT performance, ISO 10582 (Intertek, August 2023) | Glue-down LVT 3.0 mm, 0.3 mm wear layer | Thickness, stability and curling, residual indentation, colour fastness, squareness and castor chair: pass | The build tested only. |
| Reaction to fire, EN 13501-1 (Intertek, July 2022) | SPC floor, 4.0 mm total, 0.3 mm wear layer | Bfl-s1 | European classification; the build tested only. Not the 5–8 mm SPC click builds with attached IXPE. |
| EN 14041 type test (Intertek, January 2021) | One PVC floor covering build: multilayer with glass-fibre mesh, 2–10 mm total | Reaction to fire Bfl; formaldehyde E1; slip class DS | Covers that build, not all SPC, LVT, ABA or wall panels. |
| Slip, DIN 51130 (Intertek, August 2022) | SPC surface described in the report | R10 | Ramp test; the surface tested only. Not a pendulum result. |
| EPD, EN 15804 (SCS Global Services) | SPC, LVT and PP floors; European market scenario | Valid to 27 April 2031 | Voluntary; useful where a project scores environmental data. |
A report that matches your build supports the project file; on its own it does not show that a national or project requirement is met. Scope: SPC and LVT certifications.
SPC click, SPC tiles and click LVT:
builds and sizes in millimetres.
Every standard SKU has a data sheet. Not every size is made in every thickness; the grade table is on each product page. Décors are in the décor library.
Plank with a rigid mineral and PVC core, décor film and wear layer, with attached IXPE underlay. For distributor stock, apartments, offices and shops.
Thin vinyl bonded to a level screed. For malls, retail units, offices, clinics and hotels with heavy traffic, and for herringbone layouts.
Flexible vinyl with a glass-fibre reinforced core, softer underfoot than SPC. No attached underlay. For apartments, villas and hospitality on a flat, well-prepared screed.
Polypropylene-based floor for specifications that exclude PVC. Blue Angel and CE (system 1) cover this floor, not our SPC or LVT.
Stone, marble, concrete and terrazzo décors in tile formats: SPC click, flexible click, glue-down, loose lay and ABA. For retail, offices and hospitality, subject to the project specification.
Heavy vinyl with a non-slip backing and no click, replaced plank by plank. Depending on the product, area and traffic, it may need perimeter fixing or a tackifier.
On site: a glue-down floor needs a level surface suitable for the adhesive; a floating floor needs a flat, dry and sound base. Measure screed moisture before laying, especially in new buildings finished in a holiday window. See the installation guide.
Herringbone, surface, SPC wall panels and own brand
Each option is confirmed by build in the quotation.
Herringbone
A and B click boards in SPC, flexible LVT and ABA, or glue-down LVT, each with its own data sheet. For SPC click herringbone, A and B boards are packed in separate cartons.
Herringbone formats and data sheets
Chevron
Ends cut at an angle so the boards meet in a continuous point. Sizes depend on the build and the project.
Chevron formats
EIR surface
Embossed in register: the texture follows the printed grain. Available on selected wood décors, at a higher price than the standard texture.
EIR décors
Own brand (OEM)
Your brand, carton and label, quoted by build, with the minimum order confirmed for your programme.
OEM and private label
SPC wall panels
For corridors and wet-area walls, depending on the panel, substrate and fixing method. Floor fire reports do not cover wall panels. Ask for floor and wall in the same enquiry.
SPC wall panels
Production line
Made at our factory in Jiaxing, China. Production time and loading date are confirmed in the quotation. The photo shows production, not a test result.
About Ecoflors| Item | What we need from you |
|---|---|
| Areas | Classrooms, corridors, dining, libraries, with m² per area |
| Build | Glue-down LVT, SPC click, click LVT or PP floor; thickness and wear layer if known |
| Tender criteria | Emission scheme, PVC-free clause, fire class, slip test |
| Décors | Colour scheme or décor references |
| Handover | Installation window and delivery date to site |
| Delivery | Your forwarder and port, or the importer handling the tender |
Tariff classification for importers: HS 3918.10 for vinyl and SPC flooring.
Resources for your purchase
Samples and a quotation
in one request.
One form for samples, a quotation or both. To start we only need your company, a business contact and what you need. Leave open what is not settled yet.
If you like, pick décors first; they carry over to the form.
- Pick décorsAdd décors to your list in the décor library.
- Set the buildTick SKUs on a product page or describe the build in the form.
- Send one formTick Samples, Quotation or both. We reply by email.
Read the sample and courier policy before requesting samples. Privacy policy: ecoflors.com/privacy-policy.
General information for trade buyers and specifiers. Building, fire, acoustic, slip and procurement requirements differ by country and project; confirm them with the designer, fire engineer and client before ordering. Test results refer to the samples tested; whether they apply to an order is confirmed by comparing the build and the SKU.