Can your floors replace welded sheet vinyl?
No, not where the specification requires a seamless, welded or coved floor, such as operating theatres or other clinical areas set by infection-control rules. LVT and SPC are laid as planks or tiles with joints. They fit residents’ rooms, corridors, lounges and offices where the specification allows a jointed floor.
Do your floors have an antimicrobial treatment?
We do not claim an antimicrobial treatment or test for our floors. Cleaning and disinfection follow the maintenance guidance for the SKU; where the clinical team names a product or a test, tell us in the enquiry and we will say whether we have it.
Will wheelchairs, beds and trolleys mark the floor?
A 3.0 mm glue-down LVT with a 0.3 mm wear layer passed the ISO 10582 tests, including residual indentation and the castor chair test. Under frequent rolling loads, a bonded floor avoids the joint movement a floated floor can show; the designer confirms the choice. Heavier loads are checked against the data sheet of the build.
What slip data do you hold?
R10 on the DIN 51130 ramp for the SPC surface in the report, and P4 on the AS 4586 wet pendulum for a 4.2 mm SPC sample. We hold no own pendulum test to BS 7976 or EN 16165. Wet areas, ramps and entrances need the test the specification names, on the surface you order.
Which fire class can you document?
An SPC build of 4.0 mm total with a 0.3 mm wear layer is classified Bfl-s1 to EN 13501-1, and an EN 14041 type test records Bfl for another PVC build. The reports cover those builds only, not the 5–8 mm SPC click builds with attached IXPE. The class your building needs is set by the fire engineer or the specification; send it with the build you want.
The operator wants a PVC-free floor. What can you offer?
Our PP floor is PVC-free and carries Blue Angel (DE-UZ 120) for 2.0–7.0 mm with surface coating and without underlay, plus CE under EN 14041 (system 1). These documents cover the PP floor only, not our SPC or LVT.
Healthcare flooring area by area:
where a plank floor fits, and where it does not.
Healthcare buildings mix clinical and residential areas. We answer for the build and its documents; the designer, fire engineer and clinical team set the requirement; the installer confirms the base.
Build, thickness, wear layer, data sheet, test reports with their scope.
Ecoflors documents, per buildInfection-control rules, fire class, slip test, emission criteria.
Designer, clinical team, fire engineerBase flatness and moisture, adhesive, transitions, cleaning plan.
Installer, to the installation instruction| Area | Builds to consider | What to check in the specification | What Ecoflors provides |
|---|---|---|---|
| Residents’ rooms | Glue-down LVT; SPC click | Wheelchair and bed movement; slip; a residential look | ISO 10582 pass for a 3.0 mm glue-down build; wood décors |
| Corridors | Glue-down LVT | Fire class for the escape route; rolling loads; slip | Bfl-s1 for the tested SPC build; R10 for the tested surface |
| Lounges and dining | Glue-down LVT; SPC click | Slip; cleaning regime | Slip reports with their scope |
| Offices and staff areas | SPC click; click LVT | Usual commercial requirements | Data sheet per SKU |
| Clinical areas needing seamless floors | Not our plank or tile floors | Welded seams, coving, infection-control rules | We say so in the quotation rather than offer a jointed floor |
| PVC-free specifications | PP floor | Exact wording of the PVC-free clause | Blue Angel and CE (system 1) for the PP floor |
The area suggestions are starting points for the designer, not a replacement for the project specification or infection-control requirements.
Documents available
For specifiers and contractors: each report covers only the build tested. Before the order we check whether a report matches the SKU, thickness, wear layer and surface you are buying, and tell you when it does not. Report and certificate numbers are sent on request, with their scope. Data sheets and reports are in English.
| Scheme or report | Build tested / scope | Result or validity | Note |
|---|---|---|---|
| Glue-down LVT performance, ISO 10582 (Intertek, August 2023) | Glue-down LVT 3.0 mm, 0.3 mm wear layer | Thickness, stability and curling, residual indentation, colour fastness, squareness and castor chair: pass | The build tested only. |
| Reaction to fire, EN 13501-1 (Intertek, July 2022) | SPC floor, 4.0 mm total, 0.3 mm wear layer | Bfl-s1 | European classification; the build tested only. Not the 5–8 mm SPC click builds with attached IXPE. |
| EN 14041 type test (Intertek, January 2021) | One PVC floor covering build: multilayer with glass-fibre mesh, 2–10 mm total | Reaction to fire Bfl; formaldehyde E1; slip class DS | Covers that build, not all SPC, LVT, ABA or wall panels. |
| Slip, DIN 51130 (Intertek, August 2022) | SPC surface described in the report | R10 | Ramp test; the surface tested only. Not a pendulum result. |
| Slip, AS 4586 wet pendulum, Slider 96 (Intertek, February 2023) | SPC floor sample, 4.2 mm | P4 (lowest of three directions) | The surface tested only; relevant where stock is also sold into Australia. |
| FloorScore (SCS) | SPC up to 7 mm; ABA up to 7 mm; LVT up to 5 mm; loose lay up to 6 mm | Valid to 30 September 2027 | Voluntary indoor-emissions certification. 8 mm SPC and ABA are outside this scope. |
| GREENGUARD Gold (UL 2818) | Click vinyl 3.2–7.0 mm; glue-down 2.0–7.0 mm; loose lay 3.2–7.0 mm | Valid to 7 January 2027 | Voluntary VOC certification. Checked per SKU and build. |
| VOC emissions test (Eurofins, April 2026) | One PVC floor, 8.0 mm | Indoor Air Comfort GOLD limit values; AgBB; formaldehyde E1 | The tested sample only; a test report, not a product certificate. |
| Blue Angel, DE-UZ 120 | PP (PVC-free) floor 2.0–7.0 mm, with surface coating, without underlay | Awarded April 2026 | Covers the PP floor only, not SPC or LVT. |
| CE, system 1, EN 14041 | PP (PVC-free) floor | Factory production control assessed (May 2025) | PP floor only. |
A report that matches your build supports the project file; on its own it does not show that a national or project requirement is met. Scope: SPC and LVT certifications.
SPC click, SPC tiles and click LVT:
builds and sizes in millimetres.
Every standard SKU has a data sheet. Not every size is made in every thickness; the grade table is on each product page. Décors are in the décor library.
Thin vinyl bonded to a level screed. For malls, retail units, offices, clinics and hotels with heavy traffic, and for herringbone layouts.
Plank with a rigid mineral and PVC core, décor film and wear layer, with attached IXPE underlay. For distributor stock, apartments, offices and shops.
Flexible vinyl with a glass-fibre reinforced core, softer underfoot than SPC. No attached underlay. For apartments, villas and hospitality on a flat, well-prepared screed.
Polypropylene-based floor for specifications that exclude PVC. Blue Angel and CE (system 1) cover this floor, not our SPC or LVT.
Stone, marble, concrete and terrazzo décors in tile formats: SPC click, flexible click, glue-down, loose lay and ABA. For retail, offices and hospitality, subject to the project specification.
Heavy vinyl with a non-slip backing and no click, replaced plank by plank. Depending on the product, area and traffic, it may need perimeter fixing or a tackifier.
On site: a glue-down floor needs a level surface suitable for the adhesive; a floating floor needs a flat, dry and sound base. Plan thresholds for wheelchairs and beds at room transitions. See the installation guide.
Herringbone, surface, SPC wall panels and own brand
Each option is confirmed by build in the quotation.
Herringbone
A and B click boards in SPC, flexible LVT and ABA, or glue-down LVT, each with its own data sheet. For SPC click herringbone, A and B boards are packed in separate cartons.
Herringbone formats and data sheets
Chevron
Ends cut at an angle so the boards meet in a continuous point. Sizes depend on the build and the project.
Chevron formats
EIR surface
Embossed in register: the texture follows the printed grain. Available on selected wood décors, at a higher price than the standard texture.
EIR décors
Own brand (OEM)
Your brand, carton and label, quoted by build, with the minimum order confirmed for your programme.
OEM and private label
SPC wall panels
For corridors and day rooms, depending on the panel, substrate and fixing method. Floor fire reports do not cover wall panels. Ask for floor and wall in the same enquiry.
SPC wall panels
Production line
Made at our factory in Jiaxing, China. Production time and loading date are confirmed in the quotation. The photo shows production, not a test result.
About Ecoflors| Item | What we need from you |
|---|---|
| Areas | Residents’ rooms, corridors, lounges, offices, with m² per area |
| Build | Glue-down LVT, SPC click, click LVT or PP floor; thickness and wear layer if known |
| Requirements | Fire class, slip test, emission criteria, any cleaning products named |
| Décors | Colour scheme or décor references |
| Programme | Phasing if the building stays occupied |
| Delivery | Your forwarder and port, or the importer handling the project |
Tariff classification for importers: HS 3918.10 for vinyl and SPC flooring.
Resources for your purchase
Samples and a quotation
in one request.
One form for samples, a quotation or both. To start we only need your company, a business contact and what you need. Leave open what is not settled yet.
If you like, pick décors first; they carry over to the form.
- Pick décorsAdd décors to your list in the décor library.
- Set the buildTick SKUs on a product page or describe the build in the form.
- Send one formTick Samples, Quotation or both. We reply by email.
Read the sample and courier policy before requesting samples. Privacy policy: ecoflors.com/privacy-policy.
General information for trade buyers and specifiers. Building, fire, acoustic, slip and procurement requirements differ by country and project; confirm them with the designer, fire engineer and client before ordering. Test results refer to the samples tested; whether they apply to an order is confirmed by comparing the build and the SKU.